Erdal Kablo SIAF-XT


Use Areas
It is used in the production of white goods cable groups, lighting, wiring in automotive products in hot environments.TECHNICAL AND ELECTRICAL SPECIFICATIONS
- Operating Voltage-max / 300/500 V
- Test Voltage / 2000 V
- Short Circuit Voltage / 5000 V
Cable for Hot Environments
Our SIAF-XT cable with multi-wire, single core and high temperature resistant silicone insulation has demonstrated a superior success withstanding temperatures of -60ºC/+300ºC and has been It finds the range of -max 300/500V as a voltage.
Rated Section | Conductor Diameter | Linear Resistance 20°C | Outer Diameter | Reference Awg No. | ||
---|---|---|---|---|---|---|
Tinned Copper | Red Copper | Min. | Max. | |||
0.50 | 0.90 | 40.10 | 39.00 | 2.00 | 2.20 | 20 |
0.75 | 1,20 | 26.70 | 26.00 | 2.10 | 2.30 | 18 |
1.00 | 1,30 | 20.00 | 19.50 | 2.20 | 2.50 | 17 |
1,50 | 1,60 | 13.70 | 13.30 | 2.60 | 2.80 | 16 |
2.50 | 2.00 | 8.21 | 7.98 | 3,30 | 3.50 | 14 |
4.00 | 2.60 | 5.09 | 4.95 | 3,90 | 4.10 | 12 |
6.00 | 3,60 | 3.39 | 3,30 | 4.90 | 5.10 | 10 |
10.00 | 4.80 | 1.95 | 1.91 | 5.90 | 6.10 | 8 |
16.00 | 6.00 | 1.24 | 1,21 | 7.90 | 8.10 | 6 |
25.00 | 7.50 | 0.795 | 0.78 | 9.00 | 9.10 | 4 |
35.00 | 8.80 | 0.565 | 0.554 | 10.70 | 10.80 | 2 |
50.00 | 10.70 | 0.393 | 0.386 | 12.80 | 12.90 | 1 |
70.00 | 12.80 | 0.277 | 0.272 | 14.40 | 14.50 | 2/0 |
95.00 | 14.80 | 0,210 | 0.206 | 17.00 | 17.10 | 3/0 |