Erdal Kablo SIA-GL


Usage areas
It is used in the production of white goods cable groups, lighting, wiring in automotive products in hot environments.
TECHNICAL AND ELECTRICAL PROPERTIES
- Operating Voltage-max / 300/500 V
- Test Voltage / 2000 V
- Short Circuit Voltage / 5000 V
Hot Environment Cable
Our SIA-GL cable, which is single-wire, single-core and insulated with glass yarn braid on silicon, has shown a superior success withstanding temperatures of -60ºC/+180ºC and finds the operating voltage range of -max 300/500V.
Rated Section | Conductor Diameter | Linear Resistor 20°C | Dış Çap | Reference Awg No. | ||
---|---|---|---|---|---|---|
Tinned Copper | Red Copper | Min. | Max. | |||
0,50 | 0,80 | 36,70 | 36,00 | 2,20 | 2,50 | 20 |
0,75 | 0,98 | 24,80 | 24,50 | 2,40 | 2,70 | 18 |
1,00 | 1,13 | 18,20 | 18,10 | 2,50 | 2,80 | 17 |
1,50 | 1,38 | 12,20 | 12,10 | 2,80 | 3,10 | 16 |
2,50 | 1,74 | 7,56 | 7,41 | 3,30 | 3,60 | 14 |